top of page


Kitchen waste outlet
Due to the rerouting of a kitchen waste pipe, it was necessary to reconfigure our customer's internal waste outlet. This was carried out by coring a hole through the wall and redirecting the kitchen waste pipe through and down into the new gully. Once all works were completed, we cleared the site and left in a clean and tidy manner.

JDS Drainage
Dec 19, 2025


Kitchen waste pipe reroute
Our customer's kitchen waste pipe had come away from the internal stack which contained asbestos so couldn’t be disturbed. We carried out an excavation from underneath the kitchen window to the downstream chamber, installed a new gully complete with a new pipe run and connected into the chamber. Once connected, we concreted in the gully, surrounded the new pipe run in 10mm shingle and backfilled up to existing levels.

JDS Drainage
Dec 19, 2025


Chamber Cover Repositioning
Our customer was experiencing issues with a recess cover located on a customers pathway not set square to the chamber and regularly blocking. We carefully removed the slabs and broke out the area down to a suitable depth. We removed the existing frame and reset it, square to the chamber on a bed of soft sand and cement. Once set we surrounded the area in concrete to existing level. Once the concrete base had set, we reinstated the slabs to existing levels making cuts where ne

JDS Drainage
Oct 22, 2025


Soil Stack Reconfiguration
Our customer was experiencing water leaking into the shop below, and so we were asked to reconfigure and move the stack higher. We started by cutting out and removing the existing pipework and replaced with new 110mm grey waste pipe, complete with new clips. We then had to reconfigure the 2” and 1.5” waste pipes and reconnect them at suitable points of the main stack.

JDS Drainage
Sep 21, 2025


Bakery Gully Installation
This bakery was experiencing issues with waste water leaking onto the ground, causing bad smells and attracting flies. We lifted the slabs in the area and broke out, down to a suitable depth allowing space for the new gully. We then broke out a channel for the new pipework and connected the gully into the downstream chamber. We then installed the gully on a new concrete base followed by surrounding the unit in more concrete. Once all concreted in, we had to create a raised su

JDS Drainage
Aug 11, 2025


Defective Foul Pipe
Due to a defective foul pipe, we were called to carry out an excavation to expose the fault and construct a new chamber. We used a large...

JDS Drainage
Oct 5, 2023


Pipework replacement
This job was to carry out an excavation onto a 3m section of pitch fibre pipework that was badly deformed and blistered. We carried out...

JDS Drainage
Jan 6, 2022


Re-route of storm water system
For this job we were instructed to re-route a storm water pipe that had collapsed underneath the building. We carried out an excavation...

JDS Drainage
Jan 6, 2022


Drainage Replacement
A run of approximately 9m of existing pitch fibre pipework needed to be replaced with new 100mm plastic pipe at our customer's property....

JDS Drainage
Dec 8, 2021


Gully Trap Repair
This job was to dig on the bottom of a soil pipe and remove a gully trap buried underneath the concrete. We disconnected the stack and...

JDS Drainage
May 1, 2019


Soakaway access
This customer has a treatment plant which pumps the water to a soakaway after treatment. They have had problems with blockages in the...

JDS Drainage
Aug 2, 2018


Sinkhole
This was a dangerous sink hole that had formed due to a damaged rainwater pipe . We dug down to the pipework to find that a poor...

JDS Drainage
Jul 14, 2018


Pitch Fibre Pipes
This foul system was suffering from badly deformed and blistered pitch fibre pipes, a common problem with this type of pipe. I had to...

JDS Drainage
Jun 10, 2018


Soakaway failure
This property had a rainwater gully going to a soak away which was not draining. I removed the old gully and installed a upvc replacement...

JDS Drainage
Jun 6, 2018


Water main repair
This job was to find the source of a leaking water main. We cut a square in the tarmac with a petrol spinner and broke out with a small...

JDS Drainage
May 16, 2018


Cast Iron Soil Stack
This was a cast iron soil stack which had been badly split due to the cold weather. We replaced the cast iron pipework with a new plastic...

JDS Drainage
Apr 28, 2018


Cracked Rainwater Pipe
My customer's existing rainwater run had become cracked and was full of roots, preventing the water from running away from the house. I...

JDS Drainage
Apr 22, 2018


Leaking Water Main
We had to find and fix a 25mm watermain pipe which had been leaking for some time. We excavated down to a depth of 500mm to find the...

JDS Drainage
Apr 2, 2018


Soakaway Blockage
My customer was having problems with blockages in the pipework between a treatment plant and a soakaway, so wanted the pipework altered...

JDS Drainage
Mar 2, 2018


Pumping Station Investigation
This was an investigatory dig up on a foul pumping station outlet pipe. This pipe was damaged and every time the pumps would kick in, the...

JDS Drainage
Feb 21, 2018
bottom of page